Send Message
Home ProductsFront Terminal Battery

Front Terminal Sealed Lead Acid UPS Battery 12V 180Ah

Certification
China SUZHOU FOBERRIA NEW ENERGY TECHNOLOGY CO.,LTD. certification
China SUZHOU FOBERRIA NEW ENERGY TECHNOLOGY CO.,LTD. certification
Customer Reviews
This is a fantastic sourcing battery supplier, considerate service and good quality product.

—— Olga

Good Products ,Good Service,Good Battery Supplier, for producing different types of battery,like ups battery,solar battery.

—— Ravil

A reliable battery supplier, cooperation is very happy!

—— Annie

We have very strict requirements for the battery we purchase, Foberria battery meets the requirements, not only the product quality is good, but also the service.

—— Omar

I'm Online Chat Now

Front Terminal Sealed Lead Acid UPS Battery 12V 180Ah

Front Terminal Sealed Lead Acid UPS Battery 12V 180Ah
Front Terminal Sealed Lead Acid UPS Battery 12V 180Ah Front Terminal Sealed Lead Acid UPS Battery 12V 180Ah Front Terminal Sealed Lead Acid UPS Battery 12V 180Ah

Large Image :  Front Terminal Sealed Lead Acid UPS Battery 12V 180Ah

Product Details:
Place of Origin: China
Brand Name: FOBERRIA
Certification: ISO, CE, UL
Model Number: FBR12-180FT
Payment & Shipping Terms:
Minimum Order Quantity: 100 PCS
Price: Negotiable
Packaging Details: Carton with pallet
Delivery Time: 30 work days
Payment Terms: L/C, T/T,
Supply Ability: 50,000 per month

Front Terminal Sealed Lead Acid UPS Battery 12V 180Ah

Description
Nominal Voltage: 12V Capacity: 180Ah
Battery Cell Composition: Lead Calcium Separator: AGM
Case Material: ABS Item Weight: 56kg±5%
Dimensions: 560 X 125 X 317 Mm Applications: Backup Power,Solar System,Wind System; Telecommunication Equipment
OEM/ODM: Acceptable Export: Yes
Warranty: 2 Years Sealed Type: Seald
Color: Customized Color Terminal: Copper Terminal
High Light:

12V 180Ah Lead Acid UPS Battery

,

UPS 12v 180ah Battery

,

Sealed Lead Acid UPS Battery

12V 180Ah Front Terminal Sealed Lead Acid UPS Battery

 

FOBERRIA Battery offers the widest selection of front access AGM batteries and GEL batteries.

The gel technology has numerous superiorities over the equivalent AGM battery range, especially for telecommunication applications.

 

The FL type front terminal battery comes with longer lasting design life and front access connections for fast, easy installation and maintenance, and is ideally suitable for telecom outdoor equipment, renewable energy systems and other severe environments.

 

>Charging Guidelines

 

  • Ideal charging temperature: 68 degrees Fahrenheit. Avoid charging at temperatures above 122 degrees Fahrenheit.
  • In order to achieve optimum performance and long lasting, never discharge battery over 50% of it's full capacity. Avoid discharge your battery more than 80% as this will greatly damage the battery's internal components.
  • Always fully charge batteries after each use. Both under and over-charging can reduce the life of the battery.
  • Never combine different brand, different age and different capacity batteries together. This will cause serious damage to the battery.

 

 

> Specification

 

Battery Model No.

FBR12V180FT

Nominal Voltage

12V

Capacity(25ºC)

20HR(5.25V)

180Ah

10HR(5.25V)

158Ah

1HR(4.80V)

108Ah

Dimension

Length

560±2mm

Width

125±2mm

Height

316±2mm

Total height

316±2mm

Approx. Weight

55.5kg±4%

Terminal type

F13

Internal resistance

Approx 4.2mΩ

(Fully charged,25ºC)

Capacity affected by

40ºC

102%

temperature(20HR)

25ºC

100%

 

0ºC

85%

 

-15ºC

65%

Self-discharge

3month

Remaining Capacity:91%

(25ºC)

6month

Remaining Capacity:82%

 

12month

Remaining Capacity:65%

Nominal operating temperature

25ºC±3ºC(77ºF±5ºF)

Operating

Discharge

-15ºC-50ºC(5ºF-122ºF)

temperature range

Charge

-10ºC-50ºC(14ºF-122ºF)

 

Storage

-20ºC-50ºC(-4ºF-122ºF)

Float charging voltage

13.5 to 13.8V

(25ºC)

Temperature compensation:-18mV/ºC

Cyclic charging voltage

14.5 to 15V

(25ºC)

Temperature compensation:-30mV/ºC

Max charging current

54A

Max discharging current

1400A(5sec.)

Designed floating life(20ºC)

12years


 

> Structure and composition

 

Component Positive plate Negative plate Container Cover Separator Electrolyte Safety valve Terminal
Raw material Lead dioxide Lead ABS ABS AGM Sulfuric acid Rubber Copper

 

>Constant Current Discharge Characteristics(A,25ºC)
 
F.V/Time 10min 15min 30min 60min 2h 3h 4h 5h 8h 10h 20h
9.6V 381 293 175 108 65.8 46.8 37.8 32.3 22.0 18.3 9.71
9.9V 369 286 172 106 65.4 46.5 37.6 32.1 22.1 18.3 9.69
10.2V 354 276 167 104 64.8 46.2 37.3 31.9 21.9 18.2 9.66
10.5V 339 266 163 101 63.8 45.9 37.1 31.7 21.8 18.1 9.61
10.8V 320 252 157 98.3 62.2 44.5 36.0 30.7 21.1 18.0 9.54
 

 

>Constant Power Discharge Characteristics(Watt,25ºC)

 

F.V/Time 10min 15min 30min 60min 2h 3h 4h 5h 8h 10h 20h
9.60V 4111 3221 1969 1230 762 551 445 382 264 219 117
9.90V 3987 3143 1929 1212 757 547 442 380 262 218 116
10.2V 3823 3027 1870 1181 750 544 439 377 261 218 116
10.5V 3659 2924 1825 1156 739 540 436 374 259 216 115
10.8V 3453 2770 1758 1121 720 524 423 363 251 215 114

 

 

>Application

 

1. Front terminal series VRLA battery have been designed to be used in UPS system and telecom equipment.


2. Solar and wind energy storage system

 

3. Signal system , emergency lighting system , security system

 

4. Power source for portable devices or tools.

 

 

>Features

 

  • GEL Battery cell for 6V 180Ah 12V180Ah 24V180Ah 36V180Ah 48V180Ah
  • Designed floating service life: 12~15years @25°C/77°F
  • Able to operate at -15°C to +40°C
  • Deep Cycle usage: 50% DOD, 1200-1300 Cycles work in high/cold temp. area.
  • 3 years Warranty
  • Adopt Super-C additives lead plates: Deep discharge recovery capability
  • Solar power generation grid, Off Grid energy storage systems, Wind Power Systems,
  • Hybrid energy storage systems,Home energy storage systems, Telecom Station
  • Renewable energy storage, Smart power grids and micro-grids system
  • Distributed energy storage system, UPS and Inverter systems, Emergency lighting system
  • Generator and battery hybrid energy system
  • Electric Powered Vehicles, Golf Cars and Buggies, Tour bus, Sweeper, Floor cleaning machines,
  • Wheel Chairs, Power Tools, Electric Powered Toys, Control System, Medical Equipments,
  • Forklift, Marine, RV, Boat, Pumps, and so on.
  • Normal, 25-30 days for production with injection molding Lead-plate by ourself
  • As a factory we Can Support Urgent project with 10-15days.
  • OEM brand is free charge.

 

> Production Line

12V 100Ah 10Hr Deep Cycle Sealed Lead Acid Battery For UPS Solar System 4

Front Terminal Sealed Lead Acid UPS Battery 12V 180Ah 1

 

 

>Our Services

 

We accept OEM .

 

We accpet sample order for quality testing before production order.

 

After-Sale Service: Consultacncy and Technical Support

 

 

>Delivery & Payment Terms

 

 

Payment Terms T/T EXW 30% in advance for deposit payment, the balance payments will be paid before shipment.
FOB
CFR/C&F 30% in advance for deposit payment, the balance will be paid against copy of B/L
CIF
L/C For the amount of one shipment above 50,000 usd, L/C at sight is acceptable.
Delivery Time 30 days after receiving the payment or the deposit payment

 

 
 

Contact Details
SUZHOU FOBERRIA NEW ENERGY TECHNOLOGY CO.,LTD.

Contact Person: Mr. Roger Ning

Tel: +86 139 6163 5976

Fax: 86-512-50176362

Send your inquiry directly to us (0 / 3000)