Product Details:
|
Product Name: | Deep Cycle Battery | Model: | FDC12-90 |
---|---|---|---|
Nominal Voltage: | 12V | Capacity: | 90AH |
Terminal: | F13 | Dimension: | 306*169*214mm |
Weight: | 26.5kg | Battery Cell: | Sealed Lead Acid |
Guarantee: | 3Years | Reusability: | Rechargeable |
Application: | Solar Energy System | ||
High Light: | 12V90Ah Deep Cycle Lead Acid Battery,27A Deep Cycle Lead Acid Battery,26.5kg 12v lead acid deep cycle battery |
12V90Ah Low Discharge Lead Acid Battery Deep Cycle Battery systems for solar
Battery Model No. | FDC12V90Ah | |
Nominal Voltage | 12V | |
Capacity | 20HR(5.25V) | 90Ah |
(25ºC) | 10HR(5.25V) | 79Ah |
1HR(4.80V) | 55.6Ah | |
Dimension | Length | 306±2mm |
Width | 169±2mm | |
Height | 211±2mm | |
Total height | 214±2mm | |
Approx. Weight | 27kg±4% | |
Terminal type | F14 | |
Internal resistance | Approx 5mΩ | |
(Fully charged,25ºC) | ||
Capacity affected by | 40ºC | 102% |
temperature(20HR) | 25ºC | 100% |
0ºC | 85% | |
-15ºC | 65% | |
Self-discharge | 3month | Remaining Capacity:91% |
(25ºC) | 6month | Remaining Capacity:82% |
12month | Remaining Capacity:65% | |
Nominal operating temperature | 25ºC±3ºC(77ºF±5ºF) | |
Operating | Discharge | -15ºC-50ºC(5ºF-122ºF) |
temperature range | Charge | -10ºC-50ºC(14ºF-122ºF) |
Storage | -20ºC-50ºC(-4ºF-122ºF) | |
Float charging voltage | 13.5 to 13.8V | |
(25ºC) | Temperature compensation:-18mV/ºC | |
Cyclic charging voltage | 14.5 to 15V | |
(25ºC) | Temperature compensation:-30mV/ºC | |
Max charging current | 27A | |
Max discharging current | 800A(5sec.) | |
Designed floating life(20ºC) | 10years |
> Main Features
Deep Cycle battery for short DC series is specially designed for frequent cyclic performance.
By using strong grids and specially designed active material, the Deep Cycle battery offers more cyclic life than standby series.
1. Structure: compact design,shorter internal connectors between cells, thus low internal reisistance;
2. Plate: Pasted flat type, with patent deep cycle formula of AM;
3. Terminal: two or more types terminals are convenient for selection Vent system: gases can be vented through flame arrester/ filter;
4. Separator: using improved AGM separator, makes lower resistance higher assembling pressure to increase deep cycle life;
5. Battery case: made of high strength ABS(UL 94-HB) and UL 94-V0 is optional;
6. Terminal sealing; double sealing technics(mechanical + epoxy gule).
It is widely used in communication equipment, aviation signal, railway signal,alarm and safety system,
instrument and instrument system,solar energy systems, marine and RV etc.
F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
9.6V | 196 | 151 | 90.5 | 55.6 | 32.9 | 23.4 | 18.9 | 16.2 | 11.1 | 9.16 | 4.86 |
9.9V | 190 | 148 | 88.6 | 54.8 | 32.7 | 23.3 | 18.8 | 16.1 | 11 | 9.14 | 4.85 |
10.2V | 182 | 142 | 85.9 | 53.4 | 32.4 | 23.1 | 18.7 | 16 | 11 | 9.12 | 4.83 |
10.5V | 175 | 137 | 83.8 | 52.3 | 31.9 | 23 | 18.5 | 15.8 | 10.9 | 9.06 | 4.8 |
10.8V | 165 | 130 | 80.8 | 50.7 | 31.1 | 22.3 | 18 | 15.4 | 10.6 | 9 | 4.77 |
>Constant Power Discharge Characteristics(Watt,25ºC)
F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
9.60V | 2119 | 1660 | 1015 | 634 | 381 | 275 | 222 | 191 | 132 | 109 | 58.3 |
9.90V | 2055 | 1620 | 995 | 625 | 379 | 274 | 221 | 190 | 131 | 109 | 58.2 |
10.2V | 1971 | 1561 | 964 | 609 | 375 | 272 | 220 | 189 | 130 | 109 | 58 |
10.5V | 1886 | 1507 | 941 | 596 | 370 | 270 | 218 | 187 | 129 | 108 | 57.6 |
10.8V | 1780 | 1428 | 906 | 578 | 360 | 262 | 211 | 182 | 125 | 107 | 57.2 |
Contact Person: Mr. Roger Ning
Tel: +86 139 6163 5976
Fax: 86-512-50176362