Product Details:
|
Place Of Origin: | China | Product Name: | UPS Battery |
---|---|---|---|
Number: | FBR12-90 | Nominal Voltage: | 12V |
Capacity: | 90AH | Reusability: | Rechargeable |
Terminal: | F14 | Dimension: | 306*169*211mm |
Weight: | 27kg | Color: | Customized |
Feature: | Low Self Discharge | Apply: | UPS,Solar System,Electric Power Systems |
High Light: | 12v90ah UPS Battery Lead Acid,F14 Terminal Sealed Vrla Battery,306*169*211mm 12v UPS Battery |
Stable quality Sealed vrla 12v 90ah UPS lead acid battery for solar system
>Summary
1.Why UPS use lead-acid batteries?
The reason why lead acid batteries are preferred for UPS applications is the lower cost and relatively lower-tech battery
management requirements.
Lead acid battery performance degrades for several reasons. In an uninterruptible power supply,
the battery set is used in a standby power application.
2.How long do UPS lead-acid batteries last?
UPS batteries (traditional sealed lead-acid batteries) tend to have either a 5-years or 10-years design life.
Some may last for 10-15 years.
Yet performance will significantly reduce overtime to a degree where it is not safe to use in a UPS system.
So you should figure out its service life instead of design life.
Battery Model No. | FBR12V90Ah | |
Nominal Voltage | 12V | |
Capacity | 20HR(5.25V) | 90Ah |
(25ºC) | 10HR(5.25V) | 79Ah |
1HR(4.80V) | 55.6Ah | |
Dimension | Length | 306±2mm |
Width | 169±2mm | |
Height | 211±2mm | |
Total height | 214±2mm | |
Approx. Weight | 27kg±4% | |
Terminal type | F14 | |
Internal resistance | Approx 5mΩ | |
(Fully charged,25ºC) | ||
Capacity affected by | 40ºC | 102% |
Temperature(20HR) | 25ºC | 100% |
0ºC | 85% | |
-15ºC | 65% | |
Self-discharge(25ºC) | 3month | Remaining Capacity:91% |
6month | Remaining Capacity:82% | |
12month | Remaining Capacity:65% | |
Nominal operating temperature | 25ºC±3ºC(77ºF±5ºF) | |
Operating | Discharge | -15ºC-50ºC(5ºF-122ºF) |
temperature range | Charge | -10ºC-50ºC(14ºF-122ºF) |
Storage | -20ºC-50ºC(-4ºF-122ºF) | |
Float charging voltage (25ºC) |
13.5 to 13.8V Temperature compensation:-18mV/ºC |
|
Cyclic charging voltage (25ºC) |
14.5 to 15V Temperature compensation:-30mV/ºC |
|
Max charging current | 27A | |
Max discharging current | 800A(5sec.) | |
Designed floating life(20ºC) | 10years |
Component | Positive plate | Negative plate | Container | Cover | Separator | Electrolyte | Safety valve | Terminal |
Raw material | Lead dioxide | Lead | ABS | ABS | AGM | Sulfuric acid | Rubber | Copper |
F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
9.6V | 262 | 202 | 121 | 74.2 | 43.8 | 31.2 | 25.2 | 21.5 | 14.8 | 12.2 | 6.47 |
9.9V | 254 | 197 | 118 | 73 | 43.6 | 31 | 25.1 | 21.4 | 14.7 | 12.2 | 6.46 |
10.2V | 243 | 190 | 115 | 71.2 | 43.2 | 30.8 | 24.9 | 21.3 | 14.6 | 12.2 | 6.44 |
10.5V | 233 | 183 | 112 | 69.7 | 42.6 | 30.6 | 24.7 | 21.1 | 14.5 | 12.1 | 6.4 |
10.8V | 220 | 173 | 108 | 67.6 | 41.5 | 29.7 | 24 | 20.5 | 14.1 | 12 | 6.36 |
> Constant Power Discharge Characteristics(Watt,25ºC)
F.V/Time | 10min | 15min | 30min | 60min | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
9.60V | 2825 | 2214 | 1353 | 845 | 508 | 367 | 297 | 255 | 176 | 146 | 77.7 |
9.90V | 2741 | 2160 | 1326 | 833 | 505 | 365 | 295 | 253 | 175 | 146 | 77.5 |
10.2V | 2628 | 2081 | 1285 | 812 | 500 | 362 | 293 | 251 | 174 | 145 | 77.3 |
10.5V | 2514 | 2010 | 1254 | 795 | 493 | 360 | 291 | 250 | 172 | 144 | 76.9 |
10.8V | 2373 | 1904 | 1208 | 770 | 480 | 349 | 282 | 242 | 167 | 143 | 76.3 |